The 5 Heat-Load Components

Accurate sizing sums: (1) Structural transmission through panels (Q = U × A × ΔT), (2) Daily product pull-down & latent freezing load, (3) Door infiltration air changes, (4) Produce respiration heat, and (5) Internal loads from fan motors, lighting, forklifts, and defrost cycles.

18-Hour Daily Runtime Divider

Total 24-hour thermal load is divided by 16 to 18 operating hours—never 24—giving the condensing unit essential defrost recovery and thermal safety margin.

TECHNICAL FAQ ENGINEERING ANSWERS

Frequently Asked Questions

Can you size a compressor based solely on room volume (m³)?

No. Two identical 100 m³ rooms can require 3× different compressor capacities depending on daily incoming warm product tonnage and door traffic.

FACTORY-DIRECT RFQ İZMİR & GLOBAL EXPORT

Request a Turnkey Cold Storage Engineering Quotation

Share your room dimensions, target temperature, and destination port or city. Our refrigeration engineers respond with detailed heat load calculations, CAD layout, and EXW/FOB/CIF pricing.

Direct Engineering Desk

Phone / WhatsApp: +90 506 689 45 82

E-mail: export@ruzgarcooling.com

HQ & Factory: Zafertepe Mah. 533 Sk. No:9/B Yağhaneler, Konak, 35250 İzmir, Turkey

Technical Quote Request Form

Call: +90 506 689 45 82 WhatsApp